No. | 1 | 2 | 3 | 4 |
series | AC MOV | |||
type | D50H24 | D50H36 | D60H24 | D60H35.4 |
suggested rated voltage (kV) | 3.7 | 5.6 | 5.4 | 5.6 |
MCOV (kV) | 3.2 | 4.7 | 4.5 | 4.7 |
diameter (mm) | 50±1 | 50±1 | 60±1 | 60±1 |
height (mm) | 24±0.3 | 36±0.3 | 24±0.3 | 35.4±0.3 |
DC U1mA (kV) | 5.3±0.3 | 7.9±0.5 | 5.2±0.5 | 7.8±0.5 |
IL at 75% of U1mA(µA) | ≤20 | ≤20 | ≤20 | ≤20 |
Ures (kV) | 9.0±0.5 | 13.45±0.8 | 8.7±0.8 | 12.95±0.8 |
typical Ures / U1mA | 1.7 | 1.7 | 1.64 | 1.64 |
repetitive charge transfer Qrs (C) | 1.8 | 1.8 | 2.4 | 2.4 |
guaranted 2ms test current (A) | 800 | 800 | 1100 | 1100 |
max 2ms test current (A) | 900 | 900 | 1200 | 1200 |
4/10µs high current test (kA) | 100 | 100 | 100 | 100 |
nominal discharge current In (kA) | 10 | 10 | 10 | 10 |
accelerated ageing test | 115℃ 0.9*U1mA/√2 Kct ≤ 1.0 |